  "title": "Colorado Springs Fences Seven Feet or Less: Regional Building Exemption",
  "citySlug": "colorado-springs-co",
  "reviewedAt": "2026-10-24",
  "jurisdiction": "Colorado Springs, CO",
  "scope": "Regional building-permit guidance for ordinary new residential yard fences not more than seven feet, including exactly seven, inside Colorado Springs; pool barriers, retaining structures, powered equipment and separately regulated work are excluded from the ordinary exemption. City 7.4.1404 adopts the 2023 Pikes Peak Regional Building Code, whose RBC105.2.1 Building item 3 supplies the exemption; the reviewed second printing is not an exhaustive later-ordinance audit. City Planning applicability and its actual ordinary-fence application remain unresolved, with no city review declared universally required, optional or unnecessary and no exact-seven placement permission. No numerical city height, grade, setback, visibility, repair or variance entitlement is supplied; confirm zoning/PD, special sites, boundaries and separate approvals. PPRBD valuation/plan-review charges are not assigned to covered exempt work, and no all-approval total, turnaround, parcel approval or engineering design is established.",
  "articleUrl": "https://fenceadvisors.com/blog/colorado-springs-co-fence-permits-code",
  "evidenceKind": "Editorial compilation of official guidance; not original law or an approval",
  "sources": [
    {
      "id": "cos-regional",
      "label": "2023 Pikes Peak Regional Building Code, second printing",
      "url": "https://www.pprbd.org/File/ByAlias/2023PPRBC2ndPrinting",
      "locator": "RBC105.2.1 Building item 3, PDF p.12/printed p.8; RBC105.1/.3 pp.12-13; RBC106 p.16; city adoption context Appendix D",
      "version": "Existing 138-page official PDF retained, not downloaded or parsed as a whole again. Internal Second Printing June 30, 2026; relevant permit pages and existing exemption image re-read in retained October 24 evidence. September upload is not the adoption date"
    },
    {
      "id": "cos-adoption",
      "label": "Colorado Springs adoption of the regional building code",
      "url": "https://codelibrary.amlegal.com/codes/coloradospringsco/latest/coloradosprings_co/0-0-0-53858",
      "locator": "7.4.1404, complete adopted code and local-modification body",
      "version": "Retained complete official section read October 24, 2026; adopts 2023 PPRBC, referenced codes and appendices with local modifications that do not replace the ordinary fence exemption. Appendix D records Ordinance 23-16 second reading March 28, 2023"
    },
    {
      "id": "cos-exempt",
      "label": "PPRBD work exempt from permits",
      "url": "https://www.pprbd.org/Permit/PermitNotRequired",
      "locator": "Fence exemption and separate applicable requirements",
      "version": "Retained complete official guidance read October 24, 2026; corroborates not-more-than-seven regional wording, not city Planning approval or a complete pool/retaining exemption"
    },
    {
      "id": "cos-project",
      "label": "PPRBD Start a Project",
      "url": "https://www.pprbd.org/Project/Info",
      "locator": "Public project entry and fence exemption; initial wizard step",
      "version": "Retained official project information and public step-one review October 24, 2026; no wizard advancement, submission, private field list or permit purchase tested"
    },
    {
      "id": "cos-homeowner",
      "label": "PPRBD homeowner permit process",
      "url": "https://www.pprbd.org/Information/HomeownerPermit",
      "locator": "Qualifying owner/occupant role; regional exemption shorthand and separate city zoning statement",
      "version": "Retained full official body read October 24, 2026. Strict shorthand does not override inclusive adopted exemption. Its city-zoning statement remains unconfirmed by City Planning; no numerical zoning trigger published from it"
    },
    {
      "id": "cos-city",
      "label": "Colorado Springs Zoning and Standards",
      "url": "https://coloradosprings.gov/Zoning-Standards",
      "locator": "Official code-host provenance, zoning assistance and SpringsView resource",
      "version": "Retained complete city entry read October 24, 2026; city classification remains a separate question from regional building exemption. No selected parcel or PD approval"
    },
    {
      "id": "cos-fences",
      "label": "Colorado Springs fence guidance",
      "url": "https://coloradosprings.gov/planning-and-development/page/fences",
      "locator": "Fence guidance and separate city placement/measurement/visibility context",
      "version": "Retained complete city body read October 24, 2026; not reconciled into an ordinary zoning-application trigger or a current numerical design recipe. No city height/grade/visibility numbers adopted here"
    },
    {
      "id": "cos-city-code",
      "label": "Colorado Springs city fence provisions",
      "url": "https://codelibrary.amlegal.com/codes/coloradospringsco/latest/coloradosprings_co/0-0-0-53008",
      "locator": "Complete 7.4.910, city fence applicability and special conditions",
      "version": "Retained full section and related measurement review October 24, 2026; official overview 2026 S-22 through Ordinance 26-47 August 25, 2026. Separate city approval/placement endpoints remain unresolved; no absence-of-later-law certificate"
    },
    {
      "id": "cos-applications",
      "label": "Colorado Springs application checklists",
      "url": "https://coloradosprings.gov/application-checklists",
      "locator": "Scope-specific Planning, Development Plan, historic and relief entries",
      "version": "Retained complete official index read October 24, 2026; not proof every ordinary fence requires one of these applications. No generic variance or Development Plan packet imposed"
    },
    {
      "id": "cos-fees",
      "label": "PPRBD official fee schedule",
      "url": "https://www.pprbd.org/Information/FeeSchedule",
      "locator": "Appendix B valuation-based Table A and plan-examination fee basis",
      "version": "Retained full official schedule review October 24, 2026; valuation-data header June 30, 2025 is not every fee's enactment date. Rates not imposed on exempt fence work; no city Planning fee or all-approval total established"
    },
    {
      "id": "cos-map",
      "label": "Official SpringsView replacement map",
      "url": "https://experience.arcgis.com/experience/ae84852f373b43baa3c4a6934e3d742e",
      "locator": "New public map identified by official SpringsView migration notice",
      "version": "Retained official migration/provenance evidence October 24, 2026; map entry, not a rendered parcel, survey or complete boundary/PD determination"
    }
  ],
  "facts": [
    {
      "id": "exemption",
      "topic": "Positive regional building answer",
      "text": "RBC105.2.1 Building item 3 exempts fences not more than seven feet from the regional building permit. Exactly seven is included for that permit question only; this does not establish city placement permission or waive separate regulated work.",
      "sourceIds": [
        "cos-regional",
        "cos-exempt"
      ]
    },
    {
      "id": "authority",
      "topic": "Why this regional rule applies",
      "text": "City 7.4.1404 adopts the 2023 Pikes Peak Regional Building Code with local modifications. The retained adopted provisions do not replace its ordinary fence exemption. A general upload or supplement date is not a new fence-rule effective date.",
      "sourceIds": [
        "cos-adoption",
        "cos-regional"
      ]
    },
    {
      "id": "planning",
      "topic": "City Planning is a separate decision",
      "text": "The regional homeowner guidance makes a city-zoning statement not operationally reconciled with the reviewed city sources. Ask City Planning whether this fence needs an application, another clearance or no separate application. None is declared universal here.",
      "sourceIds": [
        "cos-homeowner",
        "cos-city",
        "cos-city-code"
      ]
    },
    {
      "id": "location",
      "topic": "Jurisdiction and layout",
      "text": "PPRBD serves multiple jurisdictions, while Colorado Springs zoning applies to the responsible city property. Use the city's official zoning and SpringsView resources, then establish actual lot lines and easements. The regional exemption is not a city height, grade or visibility formula.",
      "sourceIds": [
        "cos-city",
        "cos-map",
        "cos-fences"
      ]
    },
    {
      "id": "roles",
      "topic": "If separate regional work needs a permit",
      "text": "PPRBD's homeowner route is for qualifying work on a primary residence owned and occupied by the applicant, not pulling a permit for a hired contractor. These conditions concern actually permitted scope; exempt fencing alone is not directed into that application.",
      "sourceIds": [
        "cos-homeowner",
        "cos-project"
      ]
    },
    {
      "id": "fees",
      "topic": "Do not charge exempt work as permitted work",
      "text": "The regional fee schedule describes valuation and plan-review charges for applicable permits. Those rates are not assigned here to covered exempt fencing. City or special-scope fees remain conditional on the actual review; no flat fence fee or all-approval total is verified.",
      "sourceIds": [
        "cos-regional",
        "cos-fees",
        "cos-applications"
      ]
    }
  ],
  "checklist": [
    "Confirm Colorado Springs jurisdiction, zoning and actual lot lines; a postal address or regional service area is not enough.",
    "Describe the new fence's complete height, material and location; separate pool, retaining and powered components.",
    "Confirm the regional exemption covers the fence; its height threshold is not city placement permission.",
    "Ask City Planning which zoning review or application applies before work; do not assume it is required or waived.",
    "Prepare relevant site information, resolve special approvals and confirm fees only for reviews actually required.",
    "Retain written determinations and any issued approvals; arrange utility locating and follow applicable inspection instructions."
  ],
  "reuse": "Original compilation and worksheet: CC BY 4.0. Third-party source documents are not relicensed."
}